Skip Navigation
Skip to contents

Epidemiol Health : Epidemiology and Health

OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
1 "Jangho Yoon"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Fever screening and detection of febrile arrivals at an international airport in Korea: association among self-reported fever, infrared thermal camera scanning, and tympanic temperature
Kyung Sook Cho, Jangho Yoon
Epidemiol Health. 2014;36:e2014004.   Published online May 30, 2014
DOI: https://doi.org/10.4178/epih/e2014004
  • 29,862 View
  • 190 Download
  • 25 Web of Science
  • 21 Crossref
AbstractAbstract AbstractSummary PDF
Abstract
OBJECTIVES
The purpose of this research was to measure fever prevalence and the effectiveness of a fever screening procedure in detecting febrile arrivals at an international airport in Korea.
METHODS
Data were retrieved from arrivals’ health declaration forms and questionnaires for febrile arrivals at an international airport collected by a national quarantine station during the year 2012. Self-reported health declaration forms were returned by 355,887 arrivals (61% of the total arrivals). Of these, 608 symptomatic arrivals (0.2%) including 6 febrile arrivals were analyzed.
RESULTS
Fever prevalence at an international airport in Korea was 0.002%. Self-reported fever was significantly positively associated with tympanic temperature (p<0.001). The difference between the thermal camera temperature (36.83°C) and tympanic (or ear) temperature (38.14°C) was not statistically significant.
CONCLUSIONS
The findings imply that a procedure for mass detection of fever such as self-reported questionnaires and thermal camera scanning may serve as an effective tool for detecting febrile arrivals at quarantine stations. Future research can benefit from looking at the sensitivity, specificity, positive predictive value, and negative predictive value of the entry screening system.
Summary
Korean summary
2003년 전 세계적인 SARS 대 유행 이후, 우리나라는 증상을 자가보고 하도록 하는 검역질문서, 열감지 카메라를 통한 체온 측정, 고막체온 측정 등과 같은 검역절차들이 상호 유기적으로 작용할 수 있도록 검역체계를 강화해 왔다. 그러나 이러한 검역절차들이 얼마나 효과적으로 작용하고 있는지, 그리고 이를 통해 실제로 발열환자가 얼마나 발견되고 있는지에 대한 연구는 전무하였다. 그러한 점에서 본 연구는 이러한 연구 질문에 대한 우리나라 최초의 시도로서, 검역 행정뿐만 아니라 향후 보다 발전된 후속 연구를 위한 기초자료로도 활용될 수 있을 것이다.

Citations

Citations to this article as recorded by  
  • Evaluating the Impact of the Pandemic Crisis on the Aviation Industry
    Qing Ye, Rongting Zhou, Fahad Asmi
    Transportation Research Record: Journal of the Transportation Research Board.2023; 2677(3): 1551.     CrossRef
  • Development of abnormal facial temperature detection technology using thermal imaging to prevent the spread of infectious diseases
    Hyung Gil Hong, Sun Ho Jang, Hae Yong Yun, Yong Jun Cho
    Journal of King Saud University - Computer and Information Sciences.2023; 35(9): 101754.     CrossRef
  • Comparison of cutaneous facial temperature using infrared thermography to standard temperature measurement in the critical care setting
    Peter Y. Chan, Andrew Tay, David Chen, Sara Vogrin, John McNeil, Ingrid Hopper
    Journal of Clinical Monitoring and Computing.2022; 36(4): 1029.     CrossRef
  • SARS-CoV-2 (Covid-19) workplace temperature screening: Seasonal concerns for thermal detection in northern regions
    Katie A. Goggins, Emily J. Tetzlaff, Wesley W. Young, Alison A. Godwin
    Applied Ergonomics.2022; 98: 103576.     CrossRef
  • Technologies for Fever Screening in the Time of COVID-19: A Review
    Scott D. Adams, Andrew Valentine, Tracey K. Bucknall, Abbas Z. Kouzani
    IEEE Sensors Journal.2022; 22(17): 16720.     CrossRef
  • Geographic disparities in COVID-19 infections and deaths: The role of transportation
    Darrell J. Gaskin, Hossein Zare, Benjo A. Delarmente
    Transport Policy.2021; 102: 35.     CrossRef
  • Diagnostic accuracy of infrared thermal imaging for detecting COVID‐19 infection in minimally symptomatic patients
    Mario A. Martinez‐Jimenez, Victor M. Loza‐Gonzalez, E. Samuel Kolosovas‐Machuca, Mercedes E. Yanes‐Lane, Ana Sofia Ramirez‐GarciaLuna, Jose L. Ramirez‐GarciaLuna
    European Journal of Clinical Investigation.2021;[Epub]     CrossRef
  • An Overview of Thermal Infrared Imaging-Based Screenings during Pandemic Emergencies
    David Perpetuini, Chiara Filippini, Daniela Cardone, Arcangelo Merla
    International Journal of Environmental Research and Public Health.2021; 18(6): 3286.     CrossRef
  • Screening Evaporative Dry Eyes Severity Using an Infrared Image
    Qing Zhang, Yi Wu, Yilin Song, Guanghao Qin, Lanting Yang, Sumeet Singh Talwar, Tiezhu Lin, Gagan Deep Singh Talwar, Hongda Zhang, Ling Xu, Jonathan E Moore, Emmanuel Eric Pazo, Wei He, Gonzalo Carracedo
    Journal of Ophthalmology.2021; 2021: 1.     CrossRef
  • Infrared Thermography for Measuring Elevated Body Temperature: Clinical Accuracy, Calibration, and Evaluation
    Quanzeng Wang, Yangling Zhou, Pejman Ghassemi, David McBride, Jon P. Casamento, T. Joshua Pfefer
    Sensors.2021; 22(1): 215.     CrossRef
  • Automated approaches for ROIs extraction in medical thermography: a review and future directions
    Jaspreet Singh, Ajat Shatru Arora
    Multimedia Tools and Applications.2020; 79(21-22): 15273.     CrossRef
  • The Use of Digital Health in the Detection and Management of COVID-19
    Meshari Alwashmi
    International Journal of Environmental Research and Public Health.2020; 17(8): 2906.     CrossRef
  • Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review
    Bin Yang, Xiaojing Li, Yingzhen Hou, Alan Meier, Xiaogang Cheng, Joon-Ho Choi, Faming Wang, Huan Wang, Andreas Wagner, Da Yan, Angui Li, Thomas Olofsson, Haibo Li
    Energy and Buildings.2020; 224: 110261.     CrossRef
  • Manual Fever Check Is More Sensitive than Infrared Thermoscanning Camera for Fever Screening in a Hospital Setting during the COVID-19 Pandemic
    Jiwon Jung, Eun Ok Kim, Sung-Han Kim
    Journal of Korean Medical Science.2020;[Epub]     CrossRef
  • Health screening strategies for international air travelers during an epidemic or pandemic
    Lukas Gold, Esmaeil Balal, Tomas Horak, Ruey Long Cheu, Tugba Mehmetoglu, Okan Gurbuz
    Journal of Air Transport Management.2019; 75: 27.     CrossRef
  • Non-Invasive Forehead Segmentation in Thermographic Imaging
    Francisco J. Rodriguez-Lozano, Fernando León-García, M. Ruiz de Adana, Jose M. Palomares, J. Olivares
    Sensors.2019; 19(19): 4096.     CrossRef
  • Clinical and epidemiological characteristics of imported dengue fever among inbound passengers: Infrared thermometer–based active surveillance at an international airport
    Chia-ping Su, Ying-Yun Wang, Kuei-Chu Ku, Chi-Tai Fang, Eric HY Lau
    PLOS ONE.2019; 14(12): e0225840.     CrossRef
  • Effectiveness of traveller screening for emerging pathogens is shaped by epidemiology and natural history of infection
    Katelyn M Gostic, Adam J Kucharski, James O Lloyd-Smith
    eLife.2015;[Epub]     CrossRef
  • Ebola virus disease in nonendemic countries
    Samson Sai-Yin Wong, Sally Cheuk-Ying Wong
    Journal of the Formosan Medical Association.2015; 114(5): 384.     CrossRef
  • What Ebola tells us about outbreak diagnostic readiness
    Mark D Perkins, Mark Kessel
    Nature Biotechnology.2015; 33(5): 464.     CrossRef
  • Maintaining Human Health at the Border of Taiwan
    Hsiao-Hsuan Chiu, Jui-Wei Hsieh, Yi-Chun Wu, Jih-Haw Chou, Feng-Yee Chang
    Biosecurity and Bioterrorism: Biodefense Strategy, Practice, and Science.2014; 12(6): 346.     CrossRef

Epidemiol Health : Epidemiology and Health